Saratov JOURNAL of Medical and Scientific Research

Position of toric intraocular lens and rotational stability during cataract phacoemulsifca-tion in patients with astigmatism

Year: 2019, volume 15 Issue: №2 Pages: 506-510
Heading: Ophtalmology Article type: Original article
Authors: Kulikova I.L., Timofeyeva N.S.
Organization: Cheboksary Branch of S. Fedorov Eye Microsurgery Federal State Institution
Summary:

Purpose: to analyze the position of toric intraocular lens Acrys of IQ Toric in the vertical and horizontal plane and rotational stability during cataract phacoemulsifcation in patients with astigmatism. Material and Methods. The results of implantation of toric intraocular lens (TIOL) (Acrys of IQ Toric model) in 38 patients (38 eyes) after cataract phacoemulsifcation were studied. Parameters of rotational stability and the position of TIOLs (decentration and tilt) in the capsule bag relative to the vertical and horizontal plane 2 months after the operation were also studied. Results. Average values of uncorrected visual acuity were 0.8 in more than 50 % of cases. Values of decentration and tilt of the TIOL in the capsular bag did not exceed the clinically signifcant value and amounted to an average of 0.4±0.1 mm and 0.6±0.2° respectively in the horizontal plane, and 0.3±0.1 mm and 0.5±0.1° in the vertical plane. The average rotation angle of TIOL after 2 months of observation was 4.8±4.1°, with a maximum rotation angle of 19°. Correlation analysis revealed the presence of a statistically signifcant relationship of average force between the residual cylinder and the horizontal slope (r=0.52; p=0.02) and the residual cylinder and vertical decentralization (r=0.52; p=0.03). Conclusion. In most cases the parameters of TIOL position in the capsule bag (decentration and tilt) and rotational stability did not exceed clinical signifcance providing high functional results. The residual cylinder correlated with the angle of inclination and decentralization of the optical part of the intraocular lens.

Bibliography:
1 Mohammadi M, Naderan M, Pahlevani R, Jahan-rad A. Prevalence of corneal astigmatism before cataract surgery. Int Ophthalmol 2016; 36 (6): 807–17. URL: https://doi.org / 10.1007 / s10792-016-0201-z
2 Shah RL, Li Q, Zhao W, et al. A genome-wide association study of corneal astigmatism: The CREAM Consortium. Molecular Visin 2018; 24: 127–42
3 Shimizu K, Misawa A, Suzuki Y. Toric intraocular lenses: correcting astigmatism while controlling axis shift. J Cataract Refract Surg 1994; 20 (5): 523–6.4 Holland E, Lane S, Horn JD, et al. The Acrys of toric intraocular lens in subjects with cataracts and corneal astigmatism: a randomized, subject-masked, parallel-group, 1-year study. Ophthalmology 2010; 117 (11): 2104–11
5 Ahmed II, Rocha G, Slomovic AR, et al. Canadian Toric Study Group. Visual function and patient experience after bilateral implantation of toric intraocular lenses. J Cataract Refract Surg 2010; 36 (4): 609–16
6 Ale JB, Nepal J. Intraocular lens tilt and decentration: a concern for contemporary IOL designs. Ophthalmol 2011; 3 (1): 68–77. URL: https://doi.org / 10.3126 / nepjoph. v3i1.4281
7 Visser N, Ruíz-Mesa R, Pastor F, et al. Cataract surgery with toric intraocular lens implantation in patients with high corneal astigmatism. J Cataract Refract Surg 2011; 37 (8):1403– 10 URL: https://doi.org / 10.1016 / j. jcrs. 2011.03.034
8 Jung NYe, Lim DH, Hwang SS, et al. Comparison of clinical outcomes of toric intraocular lens, Precizon vs Tecnis: a single center randomized controlled trial: Contributed equally. BMC Ophthalmology 2018; 18 (1): 292 URL: https:// doi.org / 10.1186 / s 12886-018-0955-3
9 Espaillat A, Pérez O, Potvin R. Clinical outcomes using standard phacoemulsifcation and femtosecond laser- assisted surgery with toric intraocular lenses. Clin Ophthalmol 2016; 10: 555–63. URL: https://doi.org / 10.2147 / opth. s102083
10 Seth SA, Bansal RK, Ichhpujani P, Seth NG. Comparative evaluation of two toric intraocular lenses for correcting astigmatism in patients undergoing phacoemulsifcation. Indian J Ophthalmol 2018; 66 (10): 1423–8. URL: https://doi.org / 10.4103 / ijo. ijo_73_18
11 Matveeva AV, Shukhaev SV, Veselova MA. Refractive results of toric intraocular lens implantation depending on the characteristics of initial astigmatism. Modern technologies in ophthalmology 2018; (5): 217–9
12 Makurin EV. Ultrasound biomicroscopy in the study of the stability of toric intraocular lenses in patients with cor-neal astigmatism after cataract surgery. Pacifc Medical Journal 2014; (4): 71–3
13 Potvin R, Kramer BA, Hardten DR, Berdahl JP. Toric intraocular lens orientation and residual refractive astigmatism: an analysis. Clin Ophthalmol 2016; 10: 1829–36. URL: https:// doi.org / 10.2147 / opth. s114118

AttachmentSize
2019_02-1_506-510.pdf433.27 KB

No votes yet