Saratov JOURNAL of Medical and Scientific Research

Intramedullary osteosynthesis in the treatment of humerus fracture consequences

Year: 2018, volume 14 Issue: №3 Pages: 523-529
Heading: Traumatology and Orthopedics Article type: Original article
Authors: Grazhdanov К.А., Barabash А.Р., Barabash Yu.A., Kauts О.А.
Organization:
Summary:

Aim: retrospective analysis of surgical treatment results of patients with the consequences of humerus fractures by locking intramedullary constructions. Material and Methods. 69 patients with ununited fractures and false joints of humerus diaphysis (39 females, 56.7±11.5 yrs (56.5%) and 30 males, 52.3±9.8 yrs (43.5%)) comprised observation group. In the course of surgical intervention they were treated by locking intramedullary rods to perform fragment anchorage, this including 12 patients (17%) with ununited humerus diaphysis fractures after conservative treatment, and 57 (83%) with false humerus joints. Clinical (limb functional restoration) and X-ray (integrity signs) methods were applied for the diagnostics and control of integrity restoration in bone structures; for the assessment of treatment outcomes we used standardized system of outcomes of locomotor fractures and their consequences (SOI-1). Results. Consolidation of the fracture up to 6 months postoperatively was observed in all patients with ununited humerus fractures, treatment outcomes by SOI were 85-94% of anatomic and physiological norm. The consolidation of humerus bone occurred in 50 patients with false joints with

Bibliography:
1 Eldzarov РЕ, Zelyanin AS, Filippov VV. Surgical treatment of consequences of femoral fractures. Khirurgiya: Zhurnal im. N.I. Pirogova 2010; (9): 47-52
2 Neverov VA, ChernyaevAN, Shinkarenko DV. Therapeutic approach to humeral bone fractures complicated by peripheral nerve trauma. Vestnik khirurgii im. I.I. Grekova 2015; (6): 42-5
3 Barabash АР, Kaplunov AG, Barabash YuA, et al. false joints of long bones (treatment techniques and outcomes). Saratov, 2010; 130 p.
4 Zuev PP. Locking intramedullary osteosynthesis in the treatment of diaphysal ununited fractures and false joints of femoral bone. In: Classics and innovations in traumatology and orthopedics: collection of abstr. of All-Russian Science and Research Conf. to the 75-th anniversary of Prof.A. P. Barabash. Saratov, 2016; p. 147-51
5 Zuev РР, Barabash АР, Barabash YuA. Locking intramedullary osteosynthesis in treatment of femur fracture consequences. Modern problems of science and education 2017; (5): 11
6 Compression-distraction osteosynthesis in the treatment of false joints of humerus: methodological recommendations, contrib/G.A. Ilizarov, V.I. Shevtsov. Kurgan: KNIIEKOT, 1974; p. 6-7
7 Mironov SP, Mattis ER, Trotsenko VV. Standardized assessment of outcomes of locomotor fractures and their consequences. (SOI-1). In: Standardized investigations in traumatology and orthopedics. M., 2008; p. 24-6
8 Method oftreating false jointsof long bones: Pat. RF 2438608, IPC A61B17/56 / Barabash AP, Barabash AA, Grazhdanov KA, et al. Applicant and patent holder Saratov Research Institute of Traumatology and Orthopedics. №2010121613; claimed 27.05.2010; published 10.10.2012, bul. №1
9 Method of treating long healing, ununited fractures and false joints of long bones: Pat. RF 2406462, IPC A61B17/56 / Barabash YuA, Barabash AA, Balayan VD, et al. Applicant and patent holder Saratov Research Institute of Traumatology and Orthopedics. №2009133052; published 02.09.2009
10 Method of plastyof defects of long tubular bones: Pat. RF 2463012, IPCA61B17/56/Grazhdanov KA, RusanovAG.Applicant and patent holder Saratov Research Institute of Traumatology and Orthopedics. №2011130003; claimed 19.07.2011; published 10.10.2012, bul. №28
11 Nikolenko VN, Fomicheva ОА. Morphology of sources vascularization in the humerus diaphysis. Morphological newsletter 2007; 1 (1-2): 95-8.

AttachmentSize
2018_3-1_523-529.pdf925.67 KB

No votes yet